MISCIBLE Impellers Calculation-1


Home

>

Impellers

>

MISCIBLE Impellers Calculation-1

985 views

-

MISCIBLE Impellers Calculation-1
Products:
Max.Viscosity 8,000 CPS
Max.SG. 1.18
Rheology : Non-Newtonian / Thixotropy Flow (Time dependent)

6-STEP FOR AGITATOR DESIGN STANDARD

Step-1 :
Volume Calculation
Tank Dia.2300 mm x SH.2700 mm
Total/Working Volume = 2,540L/2,000L

Step-2 :
Impeller Selection
Impeller for Slurry : Turbine6B Impeller
No. of Stages Design : 1 Stage
d/D Design : 0.55
Buffle Plate : None

Step-3 :
Tip Speed Design
Degree of Mixing : Medium Mixing
Tip Speed Design : 5.5 m/sec
Calculation Impeller Speed = 84 RPM
Calculation Dia.of Impeller = 1265 mm

Step-4 :
Power Absorb Calculation
Power Calculation 19.485/22.0 kW
Ne Number : 5.96E-3
Torque : 2241.13 Nm
Specific Power 1.94 kW/m^3

Step-5 :
Shaft Calculation
Design Shaft Type : Solid
Shaft Diameter : 100 mm
Shaft Length : 2,750 mm
Steady Bearing Design : Free
Staring Torque : 5060.22 Nm
Overhung Load : 1485.96 N
Bending Moment : 4012.88 Nm
Bending Tension : 416.58 kp/cm^2
Torsion Tension : 262.74 kp/cm^2

Step-6 :
Hydraulic Data Calculation
Reynolds Number : 3.27E+2
Pumping Capacity : 11,543.04 m^3/Hr
P-Number : 1028.89
Quality Number : 18.11

สถาพร เลี้ยงศิริกูล
Miscible Technology Co.,Ltd.




Blogs